Logic Funtion
Logic Function Upon application of voltage to the input terminals, the time delay cycle starts. At the end of the preset time delay, the relay coil is energized and the contacts transfer. Reset is accomplished by the removal of input voltage.
Note 1) Remote potentiometer leads should be shielded when running close to other wires; 2) The minimum time setting on external resistor-adjustable time delay relays is obtained by shorting together the external resistor terminals of the relay; 3) The maximum time setting within tolerance limits is obtained by using a 1 megohm resistor ; 4) Timing values between the minimum and maximum limits are linear with resistance within 10%; 5) Recommend 1/4 watt minimum resistor be used.
Features
  • UR File #E59090
  • No False Contact Transfer When Reset During Timing
  • Time Delays To 10 Hours *
  • Spade Type Base
  • Wide Operating Temperature Range
  • Polycarbonate, 94V-2 Housing Material
  • 100% Life Tested
  • Digital Timing Circuit.
  • Compact In Size
  • Low Cost
  • Fiberglass Reinforced Circuit Board
  • Made in U.S.A.
Specifications
Time Delay
Adjustment: Knob or external resistor, factory fixed on special order (Minimum order required)
Range: 100 mS to 10 minutes in 9 ranges *
Repeatability: ± .5% at constant temperature and reset time, but not less than 16 mS.
Accuracy: Max. Time +(10%, +20mS) / -0%
                    Min. Time -50% / +(0%, +20mS)
Reset Time: 80 milliseconds max.

Input
Operating Voltage: 24, 120 VAC;12, 24 VDC ± 10% (D.C. models have reverse polarity protection. Unfiltered input voltage to them must be full-wave rectified)
Power Consumption: 3 VA maximum
Frequency: 50/60 Hz (AC Units)

Output
Type: Relay Contacts, D.P.D.T. (2 form C)
           Silver Cad. Oxide material

Rating: 10 amp. max. resistive at 240 VAC;
               100 mA at 5 VDC min. load current

Life: Mechanical - 1,000,000 operations
          Full Load -150,000 operations
Protection
Transient Voltage: 12 & 24 volt timers are protected by a 1 joule metal oxide varistor; 120 & 240 volt timers are protected by a 5 joule metal oxide varistor.
Dielectric Breakdown: 1500 VAC, RMS minimum at 60 Hz between input and outputs and between outputs

Mechanical
Termination: Spade (.187"x.020" terminal) type plug-in base
Mounting: Socket Mount - Part Number MSO-00KUP-012 or Flange Mount

Environmental
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

Due to a redesigned digital timing circuit, the K1 Series now offers a greater time range capability; up to 10 hours. Consult factory for details.

Pricing Shown is for Single Piece Sales - Call for Quanity Pricing or Values not Shown

Voltage
Part Number
Time Range
Cost
12 VDC
K1F-00010-566
.5 to 10 sec
$65.00
12 VDC
K1F-00060-566
3 to 60 sec
$65.00
24 VDC
K1F-00010-562
.5 to 10 sec
$65.00
24 VDC
K1F-00060-562
3 to 60 sec
$65.00
24 VAC
K1F-00010-567
.5 to 10 sec
$65.00
24 VAC
K1F-00060-567
3 to 60 sec
$65.00
120 VAC
K1F-00010-561
.5 to 10 sec
$65.00
120 VAC
K1F-00060-561
3 to 60 sec
$65.00

Sacramento Electronic Supply (916) 441-4821 - (800) 863-1711 - Fax (916) 441-6013